You may also like
Single-phase pump installations requiring a run capacitor configuration can be supplied with the RCAP option. Designed for single-phase 230Vac supply, this dual-pump panel incorporates run capacitors while retaining standard dual-pump control, sequencing, and protection functions.
The controller manages automated duty sharing and alternation across both single-phase pumps, alternating the duty pump on each start cycle and after 30 minutes of continuous running. When the standby start input closes, the standby pump is energized to assist. A 3-second staggered start delay prevents simultaneous motor starts to reduce electrical current draw and water surge. Independent electronic current sensing protects both motors with selectable 0.1–6A and 5–16A overload ranges.
The panel features a dual-pump capacitive touch keypad with status LEDs for power, system enable, level alarms, pump run status, auto/manual modes, and fault codes. An integrated visual strobe and audible buzzer alarm include smart chirp silencing. Configurable DIP switches enable Level Control (up to 5 floats) or Pressure Control (up to 3 pressure switches).
Built into a 400 x 400 x 200 mm powder-coated mild steel enclosure with an inner door, the panel is IP56 rated for outdoor mounting. Hardware includes a padlockable mains isolator, individual circuit breakers per pump, a removable gland plate, a volt-free BMS common fault output, and Modbus RTU Serial RS485 connections for SCADA.
Features
- Powder-coated mild steel enclosure measuring 400 mm high by 400 mm wide by 200 mm deep with removable gland plate
- IP56 rated with inner door, for outdoor mounting
- Run capacitors option (RCAPA) for single-phase pump operation
- Single-phase 230Vac supply voltage controlling two pumps with 240Vac switched outputs
- Automatic duty alternation on start and runtime, standby pump assist, and fault alternation
- 3-second staggered start delay to prevent simultaneous starting current draw and water surge
- Independent electronic overload protection per pump with selectable 0.1–6A and 5–16A ranges
- Dual-pump capacitive touch keypad with status LEDs, mute/reset, and mode selection buttons
- Padlockable mains isolator, individual circuit breakers, volt-free BMS fault output, and RS-485 port
Recently viewed
Last seen items